- Code 5 760mm 3m roofing lead ideal for parapet cappings and wide flashings.
- Perfect for cladding panels, gutter linings and deep weatherings.
- BS EN 12588 rolled lead for reliable performance and longevity.
- Install to LSTA and BS 6915 workmanship standards.
- 3m roll offers flexibility when cutting multiple bays.
£159.50 (price per roll / £2.75 per kg)
Fast Shipping
Same day packing
Specialist Products
All for Lead Work
24/7 Support
Unlimited help desk
Secure Payments
Credit/Debit Card
Description
Code 5 760mm 3m Roofing Lead Roll

760mm Wide Roll
3m Length
BS EN 12588 Material Standard
Why choose code 5 760mm 3m roofing lead?
The code 5 760mm 3m roofing lead roll is a premium heavy-gauge sheet widely specified for parapet cappings, deep weatherings, wide flashings, gutter linings and vertical cladding details. At 760mm wide, it provides extensive coverage while remaining manageable to dress on site, making it a staple for specialist leadworkers and heritage contractors.
Produced to the BS EN 12588 rolled lead standard, this sheet offers consistent thickness (approx. 2.24mm), reliable weight distribution and excellent malleability during forming. While BS EN 12588 specifies material quality, all installation and detailing must follow the craftsmanship principles set out by the Lead Sheet Training Academy (LSTA) and the national detailing standard BS 6915.
The 3m length allows installers to create multiple bay sections from a single roll, providing both efficiency and accuracy when working on parapets, valleys, sumps and cladding panels.
For bay sizing and coverage calculations, use our
Lead Roll Calculator.
Typical uses for code 5 760mm 3m roofing lead
This wider Code 5 roll is suitable for a wide range of structural weathering tasks, including:
- Parapet cappings with deep upstands and extended cover sections.
- Deep cladding and welted panel systems on dormers and façades.
- Wide flashings to walls, chimney stacks and pitched roof interfaces.
- Gutter linings, sumps and channels requiring robust heavy-gauge lead.
- Bay roofs and architectural projections.
- Complex weathering details where flexibility and strength are essential.
Why Code 5 is chosen for wider structural leadwork
Wider and more exposed weatherings demand a heavier gauge to withstand environmental stress and ongoing thermal movement. Code 5 760mm 3m roofing lead provides:
- Excellent fatigue resistance under repeated movement cycles.
- Enhanced rigidity for large or deep cover details.
- High durability suitable for heritage and conservation roofing.
- Reliable stability when forming welts, drips, laps and cladding panels.
Installed in accordance with LSTA and BS 6915 workmanship standards, Code 5 offers exceptional long-term performance on both residential and commercial projects.
Installation guidance
Install code 5 760mm 3m roofing lead using the LSTA manuals and the detailing principles within BS 6915, which define thermal movement requirements, joint types, lap sizes, fixings and bay limitations for Code 5 sheets.
BS EN 12588 covers the rolled lead material specification only.
For accessible summaries of installation requirements, see:
The Lead Lads — BS 6915 Summary
and
Neal Roofing — BS 6915 Overview.
After laying, always apply patination oil to reduce early weathering marks and ensure a consistent finish.
For upstand bedding and chase sealing, use mortar or
Lead Mate Sealant.
Installation essentials
- Substrate preparation: Ensure continuous support with smooth deck or parapet surfaces. Use
Lead Underlay. - Bay sizing: Follow LSTA / BS 6915 rules for Code 5 maximum bay lengths.
- Fixings: Use copper or stainless nails/clips from
Leadwork Fixings. - Jointing: Form welts, drips, laps and soldering (where permitted) to BS 6915 detailing.
- Finishing: Apply patination oil and complete all chases and terminations neatly.
Further reading & technical support
For a complete explanation of the BS EN 12588 material standard, see:
BS EN 12588 — Ultimate Guide.
Technical guidance and detailing resources can be found in
The Lead Handbook
and across our main information hub at
theleadlads.co.uk.
Professional installation examples appear at
Neal Roofing — Leadwork Services.
Recommended accessories
Combine code 5 760mm 3m roofing lead with:
Lead Underlay,
Patination Oil,
Lead Mate Sealant,
and specialist fixings from
Leadwork Fixings.
At a glance — code 5 760mm 3m roofing lead
| Product | Code 5 760mm 3m Roofing Lead Roll |
|---|---|
| Dimensions | 760mm × 3m (≈2.28m²) |
| Thickness | Approx. 2.24mm (Code 5) |
| Mass | Approx. 27.9kg/m² (≈63.6kg per roll) |
| Typical use | Parapets, cladding panels, flashings, valleys, gutters |
| Fixings | Copper or stainless nails/clips |
Figures approximate. Use BS EN 12588 for material specification and follow LSTA / BS 6915 detailing for workmanship.
| Weight | 58 kg |
|---|---|
| Brand |
Midland Lead |
| Roll Width |
760mm |
| Roll Length |
3m |
| Lead Code |
Code 5 |



Code 3 Lead
Code 4 Lead
Code 5 Lead
Code 6 Lead